Specification literacy

LED chip, nominal wattage and the number on the datasheet

Three numbers get confused in solar lighting conversations: the LED chip type, the wattage printed on the datasheet, and the power the luminaire actually draws. They are related but they are not the same thing, and a buyer who treats a catalogue wattage as a measured input power ends up comparing products that were never measured against each other. This page explains what each figure is, where the Minglong catalogue states it, and what to ask for when a tender needs more than a datasheet line.

The three figures

What each number actually tells you

LED chip typeThe chip designation used across the Minglong range is 2835, a common mid-power package used in outdoor luminaires. The chip type identifies the physical package and its thermal and electrical characteristics; it does not by itself state the output of a finished luminaire, because that also depends on how many chips are used, the optics and the driver.
Catalogue wattageThe wattage shown on each model page is a catalogue grade — the nominal label for a configuration, the way a model is named and quoted. It identifies which grade is being discussed. It is not a measurement of the input power drawn at the luminaire terminals, and it is not a lumen figure.
Luminaire outputThe catalogue standard specification for the range states an efficacy of 120 LM/W for the whole luminaire. That figure applies to the luminaire as a complete product rather than to the chip alone, and it is the basis for reading the listed LED quantity per grade against the grade itself.
LED quantityEach model page lists the LED quantity for the grade — for example 36*6 for one listed configuration. The LED count, the grade and the efficacy figure together give the picture, and none of the three should be read alone.
Panel and batteryThe listed solar panel rating and battery capacity are what determine how long the luminaire can run at that output. The battery autonomy and winter runtime guide covers how that ratio works.
Operating modeThe operating mode listed per model — light control, radar sensing, remote control or a combination — changes what the luminaire actually draws and therefore how long it runs. It is part of the configuration, not a detail.

Why the distinction matters

Three situations where the difference costs money

  1. Comparing two suppliers on a datasheet. When one supplier states a grade and the other states a measured input power, the two numbers are not comparable without knowing what each one is. A grade is a configuration label; a measured input power is a measurement of one unit under stated conditions. Ask both suppliers to state which they are quoting.
  2. Writing a tender specification. Public lighting tenders frequently specify LED actual power and lumen output rather than a nominal lamp wattage, because the nominal rating says nothing about the delivered light. A specification written only against catalogue wattage cannot be answered by a photometric file, which is the file that actually demonstrates the output.
  3. Confirming delivery against the specification. At goods-in stage, the only reliable checks are the physical label, the configuration against the order, and — where the project requires it — the photometric file that was submitted with the tender. Matching a nominal wattage to a printed wattage proves only that the label matches.

For tender and EPC supply

What to request, and when

Technical documents are matched to the BOQ before an order is confirmed, because the documents have to answer the tender rather than describe the product. The solar lighting for EPC contractors guide covers the document set.

IES / LDT photometric filesThe files that demonstrate the delivered output and the distribution pattern of a configuration. These are what a photometric specification is answered with, and they are supplied for tender and EPC projects where the specification calls for them.
DIALux / Relux reportsSimulation reports prepared against the project layout on request. They connect the photometric file to the actual site geometry, which is what turns a product file into a project answer.
Technical datasheetsIssued for the specific selected configuration, with the listed grade, LED quantity, panel rating, battery capacity and product size.
Compliance documentsCE and RoHS are the certifications confirmed for the range, along with the test report for the protection rating of the selected models. The applicable documents for a given model are confirmed during quotation.
DrawingsPole drawings, base plate and foundation references, supplied where the project requires them.
BOQ mappingThe mapping between the tender or BOQ line items and the models that satisfy them, which is what makes the quotation checkable against the document.

Reading the catalogue

Where to find each figure

Per-model figuresEach model page carries the catalogue grade, the listed LED quantity, the solar panel rating, the battery capacity and the product size for every listed configuration of that model.
Across all modelsThe model parameter library indexes 85 series and 359 configurations with the same listed parameters, which is the practical way to compare configurations rather than models.
How to read a configuration tableThe how to read a solar street light specification sheet guide separates the nominal grade from the model-specific listed values.
Which model to start fromThe solar street light buying guide covers how the application and the site inputs lead to a model, and the street light versus flood light comparison covers choosing between the two product types.
Protection ratingThe IP rating guide explains what IP65, IP66 and IP67 cover for a solar street light and which one the site position calls for.
What to sendThe model or models, the quantity, the application, the destination country, and the specification or tender documents if the project has them.

FAQ

Questions buyers ask

What LED chip does Minglong use in its solar lighting?

The LED chip used across the range is the 2835 package, with the listed LED quantity shown per catalogue grade on each model page — for example 36*6 for one listed configuration. The chip type identifies the package; the output of the finished luminaire also depends on the LED count, the optics and the driver.

Is the wattage on the datasheet the actual power the light uses?

No. The wattage shown on a Minglong model page is a catalogue grade — the nominal label identifying the configuration, the way a model is named and quoted. It is not a measurement of input power at the luminaire terminals, and it is not a lumen figure. When a specification calls for measured values, the photometric file is what answers it.

How do I compare two suppliers when one lists wattage and the other lists actual power?

Ask both to state which they are quoting. A catalogue grade is a configuration label; a measured input power is a measurement of one unit under stated conditions. Comparing the two directly without that distinction compares different things, and the lower number is not automatically the better product.

What lumens does a solar street light produce?

The catalogue standard specification for the range states an efficacy of 120 LM/W for the whole luminaire, which applies to the complete product rather than to the chip. Combined with the LED quantity listed for the grade, it gives the picture — but for a project that specifies delivered output, the IES or LDT photometric file for the configuration is the document that demonstrates it.

Can you provide photometric files and simulation reports for a tender?

Yes, for tender and EPC supply. IES and LDT photometric files are supplied where the specification calls for them, DIALux and Relux reports can be prepared against the project layout on request, and the document set is matched to the BOQ before the order is confirmed. Send the tender documents with the enquiry.

What other technical documents can I get with the order?

Technical datasheets for the selected configuration, compliance documents covering CE and RoHS together with the protection rating test report for the selected models, pole drawings with base plate and foundation references, and the commercial set including packing list, HS code and shipping documents. Which documents apply to a given order is confirmed during quotation.

Where can I see the listed parameters for a model?

On the model page itself, which shows the catalogue grade, LED quantity, solar panel rating, battery capacity and product size for every listed configuration. The model parameter library indexes 85 series and 359 configurations with the same figures for comparison across the whole range.

WhatsApp